244LD
 
◆ Model:244LD
◆ Parameters:HART, FF, FOMCOM、Temperature up to 420 ℃、 2500LB ANSI、SIL 2 Certified、FOXBORO ECKARDT

View product specs

Product Overview

The 244LD intelligent displacer level transmitters are designed to perform continuous measurements for liquid level, interface or density of liquids in the process of all industrial applications. The measurement is based on the proven Archimedes buoyancy principle and thus extremely robust and durable. Measuring values can be transferred analog and digital. Digital communication facilitates complete operation and configuration via PC or control system. Despite extreme temperatures, high process pressure and corrosive liquids, the 244LD measure with consistent reliability and high precision. For installations in contact with explosive atmospheres up to Zone 0, certificates are available. 



Structure Principle

244LD

Intelligent Displacer Transmitter with Torque Tube for Liquid Level, Interface and Density FOXBORO/ECKARDT
  K Carbon Steel 1.0460(A 105)

    Wafer Body           (Process Wetted))

  S 316L 1.4404 1.4435
  C Hastelloy C. 
  S 316L 1.4435/1.4404

Torque Tube Material
(Process Wetted)

  C Hastelloy C. 
  I Inconel 600
  1 DN80

Wafer Body Flange

  2 DN100
  3 3"
  4 4"
  C1 PN40(PN16 TO PN40)C/C   (a)

 Wafer Body  

Pressure Rating& Contact Face

  E1 PN250(PN16 TO PN250)E/E   (a)
  F1 PN160(PN16 TO PN160)N/F   (a)
  N1 PN160(PN16 TO PN160)N/N   (a)
  L1 PN250(PN16 TO PN250)L/L   (a)
  R1 ANSI Class 150 RF/RF   (b)
  R2 ANSI Class 900 (300/600/900) RF/RF   (b)
  R3 ANSI Class 1500 RF/RF   (b)
  S1 ANSI Class 150 SF/SF   (b)
  S2 ANSI Class 900 (300/600/900) SF/SF   (b)
  S3 ANSI Class 1500 SF/SF   (b)
  J1 ANSI Class 150 RJF/RJF   (b)
  J2 ANSI Class 900 (300/600/900) RJF/RJF   (b)
  J3 ANSI Class 1500 RJF/RJF   (b)
  L Left Hand Mounted   Mounting Direction: (Amplifier to body)
  R Right Hand Mounted
  without cable gland

Cable gland

  HART

HART

  -
  0C4 ATEX intrinsic safeZone0-IIC T4   (d)

Electrical Classification

  0C6 ATEX  intrinsic safeZone0-IIC T6   (c)(d)
  1C4 ATEX intrinsic safeZone1-IIC T4   (d)
  1C6 ATEX intrinsic safeZone1-IIC T6   (c)
  2C4 ATEX intrinsic safeZone2-IIC T4   (c)
  2C6 ATEX intrinsic safeZone2-IIC T6   (c)
  D0C ATEX Explosion proofZone0-IIC T6   (d)
  D1C ATEX Explosion proofZone1-IIC T6
  NFM FM Non-incendive
  FDZ FM Explosion proof  (c)
  CDZ CSA Explosion proof (c)
  FAA FM Intrinsic Safe
  CAA CSA Intrinsic Safe  (c)
  ZZZ For General Purpose Areas, No Explosion proof
  H Housing Complete Stainless Steel
without external Pushbuttons (f)

Options 

  R Remote Amplifier Mounting Kit (3m)  (e)
  B Remote Amplifier Mounting Kit (10m) (e)
  Nameplate

Nameplate

  U Overfill Protection as per VbF
(for D0C
0C40C6)

Certificates 

  V Overfill Protection As Per
WHG Environmental Pollution(
                          aAvailable with Wafer Body Flange Size 1 or 2
b
Available with Wafer Body Flange Size 3 or 4
c
pending
d
Not available with Wafer Body Pressure Rating & Contact FacecodesL1,J1,J2,J3
e
Not available with Electrical Classification FDZ,CDZ,0C6,D0C,D1C
f
Available with Electrical Classification ZZZ,0C4,1C4,2C4,0C6,1C6,2C6,D0C,D1C,FAA,NFM

Remaks

SHANGHAI XINGSHEN 2010 CopyRight| Contact Us | site map | Join Us| Careers | 沪ICP备05008623