As level varies directly with the capacitance caused by probe, with temperature compensation in measure system and special operation processing software, the measured capacitance outputs 4~20mA analog signal and RS-485 communication serial interface.
Features
l SCM intelligent design and no limitation of measure range
l Calibration between 0.2~20m, easer calibration procedure
l With universal feature and interchangeability, simple two-keys calibration
l With status and fault indication and analysis function
l PTFE probe of good corrosion resistance, applicable for acid, alkali and other corrosive liquids
l Two wire 4~20mA output, LED loop power field display.
l Auto temperature compensation of measure system
l Optional medium temperature compensation module
l Continuous liquid level, material level and interface level
l Modularization design, flexible extended functions, high interchangeability
l Perfect linearization measure, much smaller resolution measuring unit
l Superior technology, strong stability and reliability, high pressure and strong anticorrosion ability
l With self diagnosis
Order Information
UYB-2000 |
Intelligent RF Capacitance Level Transmitter |
Model |
|
P |
PPR single rod |
Probe rod |
F |
PTFE single rod |
T |
PTFE coaxial type |
L |
PTFE cable type |
|
F |
Flange connection DN25 PN2.5MPa |
Process connection |
P |
Thread connection G1''/ 1''NPT |
R |
Sanitary,three-blade sanitary flange DN25 |
G |
other connection to be specified |
|
H |
HART |
Options |
W |
External displacer |
B |
Wave proof pipe |
D |
Ex-proof: ExdIIBT4~T6 |
E |
Intrinsic safe: ExiaIICT4~T6 |
|
□ |
Mounting height(mm) |
|
□ |
Measure range(mm) |