Universal level switch
RF admittance level switch
◆ Model:UDE-507
◆ Parameters:UDE-507、Anti-attachment、Interference-free、 Good commonality、Pressure up to 10MPa
Product Overview
UDE-507 RF admittance level switch is a new level instrument. With advanced RF admittance technology, it has conquered the defect that capacitance level transmitter cannot eliminates influence of conductive medium attachment. Reliable in operation, resistant in heavy attachment, it is almost suitable for almost all industrial fields. In addition, it is easy to install, free maintenance, low cost and widely applied in the industries of petroleum, chemical, metallurgy, pharmacy, electric power, food stuff and paper making etc.
Structure Principle
An RF Admittance level sensor uses a rod probe and RF source to measures the change in admittance. The probe is driven through a shielded coaxial cable to eliminate the effects of changing cable capacitance to ground. When the level changes around the probe, a corresponding change in the di-electric is observed. This changes the admittance of this imperfect capacitor and this change is measured to detect change of level.
Order Information
UDE-507 |
RF Admittance Level Switch |
Model No |
|
C |
110VAC DPDT relay contact output |
Power & switch output |
F |
220VAC DPDT relay contact output |
H |
24VDC DPDT relay contact output |
|
1 |
standard: for liquid, light slurry,granule measuring; material: 316SS and PTFE |
120℃/1.5Mpa 80℃/3.0Mpa |
Probe type, rated temp. &pressure |
2 |
Mid-temperature: for liquid, light slurry,granule measuring; material:316SS and PPS |
120℃/2.5Mpa 230℃/1.5Mpa |
3 |
High temperature: for liquid, light slurry,granule measuring; material: 304 and alumina ceramics |
normal pressure/800℃ |
4 |
flat probe: for feed tank and hopper plug checking; material: 304SS and Polyurethane |
149℃/0.007Mpa |
5 |
heavy probe attachment std.:for stirred liquid, high density slurry, granule measuring. Material:316SS and PTFE |
150℃/4.0Mpa 232℃/1.38Mpa |
6 |
flexible probe: for high/low material level with insertion depth>15mm; material :304SS and rubber |
80℃/normal pressure |
7 |
anti-corrosion: for corrosive liquid, light slurry and granule measuring; material: PTFE |
120℃/1.5Mpa |
|
F20 |
DN20 flange conn. |
Process connection |
F25 |
DN25 flange conn. |
F40 |
DN40 flange conn. |
F50 |
DN50 flange conn. |
F11 |
M27×2 threaded conn. |
F12 |
G1'' threaded conn. |
F13 |
G11/2'' threaded conn. |
F14 |
1''NPT |
F15 |
11/2''NPT |
S |
special requirement. |
|
O |
no explosion proof. |
Safety class |
D |
explosion-proof: ExdIICT4 |
E |
intrinsic safe: ExizCT4~T6 |
|
□ |
probe length |
Effective length(mm) |
|